| Specifications | ||
| Model | InfiniSolar 10KW | |
| PHASE | 3-phase in / 3-phase out | |
| RATED OUTPUT POWER | 15000 W | |
| MAXIMUM CHARGING POWER | 15000 W | |
| GRID-TIE OPERATION | ||
| PV INPUT (DC) | ||
| Maximum DC Power | 22500W | |
| Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC | |
| Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | |
| MPP Voltage Range | 400 VDC ~ 800 VDC | |
| Number of MPP Trackers / Maximum Input Current | 2 / A: 37.65A and B: 18.6A | |
| GRID OUTPUT (AC) | ||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
| Output Voltage Range | 184 – 264.5 VAC * per phase | |
| Nominal Output Current | 21.7A per phase | |
| Power Factor | > 0.99 | |
| EFFICIENCY | ||
| Maximum Conversion Efficiency (DC/AC) | > 96% | |
| European Efficiency@ Vnominal | > 95% | |
| OFF-GRID OPERATION | ||
| AC INPUT | ||
| AC Start-up Voltage/Auto Restart Voltage | 120 – 140 VAC per phase / 180 VAC per phase | |
| Acceptable Input Voltage Range | 170 – 280 VAC per phase | |
| Maximum AC Input Current | 40A | |
| PV INPUT (DC) | ||
| Maximum DC Voltage | 900 VDC | |
| MPP Voltage Range | 350 VDC ~ 850 VDC | |
| MNumber of MPP Trackers / Maximum Input Current | 2 / A: 37.65A and B: 18.6A | |
| BATTERY MODE OUTPUT (AC) | ||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
| Output Waveform | Pure Sinewave | |
| Efficiency (DC to AC) | 91% | |
| HYBRID OPERATION | ||
| PV INPUT (DC) | ||
| Nominal DC Voltage / Maximum DC Voltage | 720 VDC / 900 VDC | |
| Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | |
| MPP Voltage Range | 350 VDC ~ 850 VDC | |
| Maximum Input Current | 2 / 2 x 18.6A | |
| GRID OUTPUT (AC) | ||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
| Output Voltage Range | 184 – 265 VAC * per phase | |
| Nominal Output Current | 21.7A per phase | |
| AC INPUT | ||
| AC Start-up Voltage/Auto Restart Voltage | 120 – 140 VAC per phase / 180 VAC per phase | |
| Acceptable Input Voltage Range | 170 – 280 VAC per phase | |
| Maximum AC Input Current | 40A | |
| BATTERY MODE OUTPUT (AC) | ||
| Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | |
| Efficiency (DC to AC) | 91% | |
| BATTERY & CHARGER | ||
| Nominal DC Voltage | 48 VDC | |
| Maximum Charging Current | Default 60A, 5A – 300A (Adjustable) | |
| GENERAL | ||
| PHYSICAL | ||
| Dimension, D x W x H (mm) | 219 x 650 x 820 | |
| Net Weight (kgs) | 62 | |
| INTERFACE | ||
| Communication Port | RS-232/USB and Dry contact | |
| Intelligent Slot | Optional SNMP, Modbus, and AS-400 cards available | |
| ENVIRONMENT | ||
| Humidity | 0 ~ 90% RH (No condensing) | |
| Operating Temperature | -10 to 55°C | |
| Altitude | 0 ~ 1000 m** | |
| *These figures may vary depending on different AC voltage and country requirements. | ||
| * * Power derating 1% every 100 m when altitude is over 1000m. | ||
| Product specifications are subject to change without further notice | ||